Bassam,
While I am admittedly myopic, I don't see a problem with extending the formal definition to support synchronous abort. The current definition (in B.3.1.2.2, Semantics of clocked FL) is:
v|=(c) phi abort b <==>
either
v|=(c) phi
or
there exists j<|v| s.t. v^j |= b and v^(0..j-1)T^(omega) |=(c) phi
I would think that we would only need to change
v^j |= b
to
v^j |=(c) b
to make the abort sensitive to the clock context. (Whether this might create other issues within the formal semantics, I don't know.)
Yes, you can get the same effect by 'tweaking' the abort condition - e.g.,
always (a -> b)@clk abort (c&&clk);
but by that argument we don't need clock expressions at all: every condition could be 'and'ed with the clock. The point of having a clock expression is to factor out the clock and make it easy to specify a synchronous property, so it is strange not to apply it consistently.
I agree that if support for synchronous reset is important enough for PSL to adopt, then it is also important enough for SVA to adopt. The fact that you have already raised the same issue in the SVA committee suggests that there is some reason to support this in both languages.
Regards,
Erich
| -----Original Message-----
| From: Bassam Tabbara [mailto:bassam@novas.com]
| Sent: Wednesday, December 15, 2004 1:25 PM
| To: Erich Marschner; 'Johan Mårtensson'; 'Cindy Eisner';
| dana.fisman@weizmann.ac.il
| Cc: ieee-1850-extensions@eda.org
| Subject: RE: Group A - first draft LRM changes
|
| Erich,
|
| First off I agree with you about practicality, and the fact
| that the informal LRM description can be reasonably and
| easily overloaded to mean this (but not formal defs). I
| wanted to note 2 things here:
|
| 1) We also had a similar discussion in the context of SVA
| recently where I suggested this same "natural fix" to disable
| iff (but no sale) and John pointed out the formal semantics
| of SVA and alignment to PSL's semantics (which Johan cites).
| 2) Other users on SVA committee also pointed out that an
| "asynchronous" is general enough, so by tweaking the abort
| condition to be synchronous you can get the synchronous
| overall effect, albeit it's not as easy/practical as the
| suggestion you make below.
|
| I'm not sure if "alignment" considerations are of utmost
| importance here necessarily, just a point of reference as it
| were if it indeed is something to keep in mind. It works both
| ways: If the change is deemed worthwhile in PSL, SVA should
| consider this issue again in the future.
|
| Thx.
| -Bassam.
|
| --
| Dr. Bassam Tabbara
| Architect, R&D
| Novas Software, Inc.
| (408) 467-7893
|
| -----Original Message-----
| From: owner-ieee-1850-extensions@eda.org
| [mailto:owner-ieee-1850-extensions@eda.org] On Behalf Of
| Erich Marschner
| Sent: Wednesday, December 15, 2004 8:37 AM
| To: Johan Mårtensson; Cindy Eisner; dana.fisman@weizmann.ac.il
| Cc: ieee-1850-extensions@eda.org
| Subject: RE: Group A - first draft LRM changes
|
| Johan,
|
| Again, I'm not sure I follow your example (did you mean a
| abort b instead of b abort a?), but in any case I see now
| that both the clock rewrite rules and the formal semantic
| definition in B.3.1.2.2 reflect your statement that the abort
| condition is not affected by the clock context.
|
| I believe this is a problem, from a practical point of view.
| The abort clause is the natural way to represent interrupts
| and reset operations, and these can be both synchronous or
| asynchronous. PSL should allow the user to control whether
| the abort condition represents a synchronous or an
| asynchronous event, and the way to do that is to allow the
| user to clock it or not, as appropriate. Thus if I write
|
| always (a -> b abort c)@clk
|
| I would expect the abort condition to be synchronous; whereas
| if I write
|
| always (a -> b)@clk abort c
|
| I would expect the abort condition to be asynchronous.
|
| I see that there may be some issues with nested aborts, or
| equally with top-level aborts in the context of a default
| clock declaration, because (if abort were defined such that
| it is affected by the clock context) it seems difficult to
| protect the abort condition from the influence of an outer
| clock (e.g., to define an asynchronous abort within a
| synchronous context) without changing the abort condition to
| a property, which is not allowed.
| For example, assuming that abort is affected by the clock
| context, then
|
| default clock = clk2
|
| always (a -> b)@clk abort c -- abort would be
| synchronous w.r.t.
| clk2
| always (a -> b)@clk abort c@True -- illegal because
| abort requires a
| Boolean
|
| But we could still write
|
| always ((a -> b)@clk abort c)@True -- True hides clk2
| for the entire
| property
|
| so this shouldn't be an issue.
|
| It would seem to be straightforward to define abort in such a
| way that the clock context applies to the abort condition as
| well as to the property.
| Cindy, Dana, can either of you comment on why this wasn't done?
|
| Regards,
|
| Erich
|
|
|
|
| | -----Original Message-----
| | From: Johan Mårtensson [mailto:johan.martensson@safelogic.se]
| | Sent: Wednesday, December 15, 2004 10:51 AM
| | To: ieee-1850-extensions@eda.org; Erich Marschner
| | Subject: Re: Group A - first draft LRM changes
| |
| | Erich,
| |
| | in fact nested aborts are asyncronous with resepect to the clock in
| | the environment. The simplest way to see this is in the
| case for abort
| | in the clock rewriting rules (B.5):
| |
| | F^c(phi abort b) ==> F^c(phi) abort b
| |
| | which means that the abort condition b is left entirely
| untouched by
| | the clock rewriting and will thus abort on the first
| occurrence of b,
| | whether or not it occurs on a clock instance.
| |
| | We can also go through a simple example using the formal
| semantics for
| | clocked FL (B.3.1.2.2) directly
| |
| | Let v be a word with the following truth values for a, b and c
| |
| | t: 0123456....
| | a: 0100000....
| | b: 0000000....
| | c: 0010010....
| |
| | let v|c be the word containing only those letters of v
| where c is true
| |
| | t: 25....
| | a: 00....
| | b: 00....
| | c: 11....
| |
| |
| | I will use the following symbolism (a_1,...a_n) is a letter
| | (state) in which signals a_1,..,a_n and no others are true and
| | <l_0,l_1,....> is a word defined by letters l_1,l_2,...
| |
| | Thus v above can be defined as <(),(a),(c),(),(),...> if a, b and c
| | are the only signals, and v|c as <(c),(c),(c),...>
| |
| | It is easy to see using the definition in B.3.1.2.2 that
| |
| | v|= (b abort a)@c
| |
| | but
| |
| | not v|c |= b abort a
| |
| | Best Regards, Johan M
| |
| |
| |
| | On Wed, Dec 15, 2004 at 07:22:49AM -0800, Erich Marschner wrote:
| | > Johan,
| | >
| | > I don't follow this part of your comment:
| | >
| | > | ((always a) abort b)@c is true in the following situation
| | (because
| | > | it is equivalent to (always a)@c abort b.)
| | >
| | > I would think that the @c would apply to "abort b" as well
| | as to (always a), so I wouldn't expect ((always a) abort b)@c to be
| | equivalent to ((always a)@c abort b).
| | >
| | > Can you explain why this equivalence should hold?
| | >
| | > Regards,
| | >
| | > Erich
| | >
| | >
| | > | -----Original Message-----
| | > | From: Johan Mårtensson [mailto:johan.martensson@safelogic.se]
| | > | Sent: Wednesday, December 15, 2004 9:33 AM
| | > | To: ieee-1850-extensions@eda.org; Erich Marschner
| | > | Subject: Re: Group A - first draft LRM changes
| | > |
| | > | Hi Erich,
| | > |
| | > | I have a comment below on your
| | > |
| | > | > 4. Correct the informal semantics of '@' to allow for a
| | > | nested subelement that has a different clock context.
| | > | >
| | > | > - in Clause 6.1.2.5, Clocked SERE, change the informal
| | > | semantics to read
| | > | > as follows: "For unclocked SERE A and Boolean CLK: A@CLK
| | > | holds tightly
| | > | > on a given path iff CLK holds in the last cycle of the
| | > | given path, and
| | > | > A holds tightly on the path obtained by extracting the
| | > | from the given
| | > | > path exactly those cycles in which CLK holds, and any
| | subordinate
| | > | > sequences of A hold tightly as specified by A on the
| | corresponding
| | > | > sub-paths of the given path."
| | > | >
| | > | > - in clause 6.2.1.2, Clocked FL properties, change
| the informal
| | > | > semantics to read as follows: "For unclocked FL property
| | > | A and Boolean
| | > | > CLK: A@CLK holds on a given path iff A holds on the path
| | > | obtained by
| | > | > extracting from the given path exactly those cycles
| | in which CLK
| | > | > holds, and any subordinate properties of A hold as
| | > | specified by A at
| | > | > the corresponding cycles of the given path."
| | > | >
| | > | > [Note: I'm not happy with this yet, but this is the
| | best I've been
| | > | > able to do so far.]
| | > | >
| | > |
| | > | Note that there is not only a problem with nested clocked
| | > | subproperties here. Also nested aborts break the clock
| projection
| | > | hypothesis. For instance the property
| | > |
| | > | ((always a) abort b)@c is true in the following situation
| | (because
| | > | it is equivalent to (always a)@c abort b.)
| | > |
| | > | c:0101010...
| | > | a:0100000...
| | > | b:0010000...
| | > |
| | > | whereas
| | > |
| | > | ((always a) abort b) is not true in
| | > |
| | > | a:100...
| | > | b:000...
| | > |
| | > | which is the path obtained when extracting from the given
| | path those
| | > | cycles in which c holds.
| | > |
| | > | It seems this problem with abort and clock projection is
| | not noted
| | > | in the current informal semantics in 6.2.1.2 either.
| | > |
| | > | Best Regards, Johan M.
| | > |
| | > | --
| | > | ------------------------------------------------------------
| | > | Johan Martensson, PhD Office: +46 31 7451913
| | > | R&D Mobile: +46 703749681
| | > | Safelogic AB Fax: +46 31 7451939
| | > | Arvid Hedvalls Backe 4 johan.martensson@safelogic.se
| | > | SE-411 33 Gothenburg, SWEDEN
| | > | PGP key ID A8857A60
| | > | www.safelogic.se
| | > | ------------------------------------------------------------
| | > |
| | > |
| | > |
| |
| | --
| | ------------------------------------------------------------
| | Johan Martensson, PhD Office: +46 31 7451913
| | R&D Mobile: +46 703749681
| | Safelogic AB Fax: +46 31 7451939
| | Arvid Hedvalls Backe 4 johan.martensson@safelogic.se
| | SE-411 33 Gothenburg, SWEDEN
| | PGP key ID A8857A60
| | www.safelogic.se
| | ------------------------------------------------------------
| |
| |
| |
|
|
|
|
|
Received on Wed Dec 15 11:22:38 2004